Nexygen Plus Software User Manual

Posted : admin On 4/20/2019
  1. Download Nexygen software user manual, Exe Nexygen plus. Download Nexygen Plus User Manual related programs and software, check Nexygen Plus.
  2. The NEXYGENPlus is the hub of the Lloyd Instruments materials testing systems. With the NEXYGENPlus software as part of the materials testing system, the user can simply select from the extensive library of pre-defined test setups based on international standards or create an advanced multi-stage test, all using the same program.

NEXYGEN DF software expands the functionality of your CHATILLON Series digital force gauge. This all-new and easy-to-use Windows® based package interfaces directly to your digital force gauge. You may perform break tests, limits tests and torque tests. You can download peak load results from the gauge and display your results in tabular and graphical formats. Graphical results include markers denoting exact point positions. Results can be color coded for immediate pass/fail recognition. You can easily specify units of measure, fonts, titles, force measurement resolution. The software provides basic force measurement tensile and compression test formats including pull to break, pull to limit, compress to rupture and compress to limit. Results are presented in a spreadsheet format so you can analyze and manipulate data and perform common mathematical and statistical calculations.

The software is easy to setup and features intelligent prompts, menus, combo boxes and other methods to get you up and running quickly and effi ciently with minimal training. Navigation is simple using ?drag & drop? and cut, copy and paste techniques. Data is easily exported to WORD®, EXCEL®, ACCESS®, POWERPOINT® or OUTLOOK®.

NEXYGEN™ PLUS Materials Testing Software. “User System” is a single CPU. READ THIS MANUAL BEFoRE USING THE MATERIALS.

Test Function Descriptions

Pull to Break
This test will deform a sample until the sample breaks. The force required to break the sample and the deformation at which the break occurred are measured. Users may enter sample dimensions to record stress and strain.

Pull to Limit
This test is similar to the Pull To Break test, however, it is typically used when you are not expecting the sample to break. Instead, the test will deform the sample a specifi ed amount, either with a specifi ed force or to a specifi ed defl ection point.

Compress to Rupture
This test will deform a sample until the sample breaks. The force required to break the sample and the deformation at which the break occurred are measured. Users may enter sample dimensions to record stress and strain.

Compress to Limit
This test is similar to the Compress To Rupture test, however, it is typically used when you are not expecting the sample to rupture. Instead, the test will deform the sample a specifi ed amount, either with a specifi ed force or to a specifi ed defl ection point.

Software

Torque to Break
This test will measure the torque required to break a sample. The torque required to break the sample and the direction of applied torque are recorded.

Torque to Limit
This test allows the user to apply and measure torque to a specifi ed limit. Direction of torque is recorded. 10 4 6 full install dvd driver.

Features:

Nexygen Plus Software User Manual

  • Simple to Setup and Operate
  • Interface Directly to your Chatillon Digital Gauge
  • Seamless Integration with WORD, EXCEL, ACCESS
  • Graphical and Tabular Results
  • Pre and Post-Test Analysis
  • Mathematical Calculations including Statistics
  • Pass - Fail Function
  • ISO TickIT Accreditation
Test Functions
  • Pull to Break
  • Pull to Limit
  • Compress to Rupture
  • Compress to Limit
  • Torque to Break
  • Torque to Limit
Minimum System Requirements
  • Pentium Processor, 166 MHz
  • 16 MB RAM
  • 35 MB Hard Disk Space
  • 1 Free COM Port, with 16550 UART
  • CD ROM Drive (for Installation)
Users should be provided Administrative Rights on the personal computer where the software will be installed
Manual

Nexygen DF software may be used with the following Chatillon force gauges only.

  • E-DFE Series
  • DFIS Series
  • DFS Series
  • DFS-II Series
  • DFT Series
  • DFS-R Series
  • DFS-II-R Series
  • DFGS Series
  • DFS-R-SLC Series (load)
  • DFGS-R Series
  • DFS-R-STS Series (torque)
  • DFA Series
  • DFA-R Series
  • DTG Series
Lloyd Instruments

NEXYGENPlus 3 multi-lingual materials testing software is the hub of the Lloyd Instruments materials testing system. This extraordinarily easy to use and flexible software, allows the operator to control and monitor all aspects of the system from a single front end. This provides a fast, reliable and powerful testing and data analysis for tensile, compression, tear, peel, friction, food, creep, relaxation and flexural test applications.

Designed for use with Windows©XP or Windows©7.

Test Creation Based on International Standards

Nexygen Plus Software

If your test follows an international standard, simply select the test from one of our pre-defined test procedures. If you prefer to configure your own test, the test creation wizard will simply guide you through. Almeea.

  • Large built-in library of test methods meeting
    international test standards
  • Intuitive User Configurable Test facility
  • Video and still capture for visual analysis
  • User access settings and data traceability enabling
    compliance with FDA 21 CFR Part 11
  • Built in SPC functionality for continuous monitoring of
    process parameters such as Cp and Cpk
  • Microsoft Office® integration for seamless transfer of
    data to familiar Windows® packages, Windows® 7
    compatible
  • Versatile data export facility to LIMS, SPC or data
    management systems
  • Test automation and batch testing
ProductPart No.Description
NEXYGENPlus 340/0783NEXYGENPlus 3 software
NEXYGENPlus 3 L40/0783/LAdditional Licence Agreement
NEXYGENPlus 3 U40/0783/UUpgrade from NEXYGENPlus

NEXYGENPlus3 Data Analysis and Materials Testing Software

Request a Quote